Phase Cut & 0-10V Dimming Controller EUMA0405-DDL
Summary
Thanks for using the EUMA0405 phase cut controller. The product adopts advanced MOS-FET control technology, can accurately realize the phase cut function, and has no requirement for the type or capacity of load. The compatibility is far superior to leading edge controller.
Control mode of EUMA0405 is flexible, which complies with 4 control protocols:
1, support the international widely adopted DMX-512 (1990) /RDM and DALI standard protocol, and can access KNX, Dynalite, Lutron, Crestron, LDS and other intelligent dimming network via gateway.
2, support EU-BUS lighting control protocol developed by EUCHIP. It can be used with relay switch controller, clock module, panel module, sensor module to achieve the group and scene control through the Euchips9 PC software. This solution is widely used in the family, conference rooms, hotels, schools, and other occasions.
3, support Touchdim, manual control, timing control function (optional).The user can manually turn ON/OFF or dim the brightness.
Technical Parameters
Item | Parameters |
Input voltage | 100-240VAC |
Input control signal | DMX512(1990)/RDM,DALI IEC62386,EU-BUS |
Maximum output current of phase cut | 5A*4(AC MOSFET, please take 5A*PF as output current limit for each circuit ) |
Maximum output signal current | 20mA*4(for DC0-10V ) |
Maximum inrush current limit per channel | 100A |
Equipment size | 222.5*93.4*63.2mm(L*W*H),standard 35mm |
Packing size | 226*100*68mm(L*W*H) |
G.W. | 975g |
Operational temperature | -20-50℃ |
Equipment size (mm)
Function Show of the product
1 |
AC input port |
2 |
4 AC MOSFET output ports, corresponding with 4 DC 0-10 V ports of 5 from left to right in proper order. For each channel, and the addresses of both AC MOSFET and the corresponding 0-10V are shared. |
3 |
LCD display |
4 |
Function button |
5 |
4 DC analog voltage output ports(0-10V) |
6 |
DMX 512/RDM,EU-BUS signal port(Don’t use DMX 512/RDM and EU-BUS protocol
simultaneously, they share the same terminals) |
7 |
DALI signal port |
8 |
Emergency switch |
LCD function
After a successful connection, the menu will be seen in Figure 2. Press the button "ENTER" to enter the sub menu as shown in Figure 3, press "BACK" to return to the upper menu, press "UP" or "DOWN" button to move the cursor up or down.
Button | Function |
ENTER | Confirm key, confirm the selected state, enter the option to set the state |
BACK | Return key, return to the upper menu, exit the option to set the state |
UP | Move up the cursor; change the status of the option |
DOWN | Move down the cursor; change the status of the option |
In this menu, the current system information can be displayed, which is shown as follows:
Page 1: control mode and output type
Page 2: control mode and fade time
Page 3: control mode and threshold Others except the last page: event status and event content
Last page: product model and the current time
Emergency Switch Function
4 channel output, each channel corresponds to a button. If the channel has output, press the button to switch off the 0-10V channel and the corresponding phase cut channel output. If the channel doesn’t have output, press the button to switch on the 0-10V and the phase cut channel output.
Wiring Diagram
EUMA0405 dimming module signal port can be connected to EU-BUS network, DMX512/RDM or DALI master, and also can be access to Dynalite system via the Dynalite gateway. This device outputs 4 DC0-10V signal and 4 AC phase cut signal.
EUMA0405 device can drive 4 channel DC0-10V dimming power supply and 4 channel phase cut dimming power supply at most.
The maximum current of each channel of 0-10V is 20mA, the maximum number of 0-10V dimming power which can be connected to each channel is determined by signal interface current consumption.
The maximum number of the phase cut dimming power supplies which can be connected to each channel is determined by watts and PF, such as, the power factor of the filament lamp is 1, the max load of each channel is 5*220V*1=1100 watts, but at present, the LED lamp is widely used, the PF of led dimmable lamps and dimmable drivers is low, it is recommended that the power of each channel is not more than 800 watts. When the impact current of phase cut dimmable lamps or drivers is more than 100A,the device may protect themselves and can not start (Impact protection function is provided to avoid broken),the fault information will be shown at LCD. In this situation, please set longer fade time to restart the device slowly.