60-96 W 0-10V/DIP/PWM Dimmable Driver ARC DI 60-96 W S Series
Features
· Supply Voltage 108-382Vac
· Great Surge Immunity 2.5k(ringwave)
· 50000Hour Life @ Tc=90℃
· 5Year Warranty@Tc<=90℃
· ±5% Output Current Accuracy
· 0-10V/DIP Dimmable
· UL Class P, Class 2
· Safety according to UL8750 & UL 1310
Model No. | Input Voltage(VAC) |
Input Current(A) |
PF | Output Voltage(VDC) |
MAX Output power(W) |
MAX Iout(mA) |
Eff(Max) | Life at Tc 90℃(h) |
ARC-DI-96I3000-UNV-DI-S | 120-277 | 1.1(Max) | 0.90 | 24-32 | 96 | 3000 | 88% | 50000 |
ARC-DI-96I1200-UNV-DI-S(EX) | 120-277 | 1.1(Max) | 0.90 | 24-32 | 96 | 3000 | 88% | 50000 |
ARC-DI-96I3000-UNV-DI+D3-S | 120-277 | 1.1(Max) | 0.90 | 24-32 | 96 | 3000 | 88% | 50000 |
ARC-DI-96I3000-UNV-DIS-S | 120-277 | 1.1(Max) | 0.90 | 24-32 | 96 | 3000 | 88% | 50000 |
ARC-DI-96I1200-UNV-DIS-S(EX) | 120-277 | 1.1(Max) | 0.90 | 24-32 | 96 | 3000 | 88% | 50000 |
ARC-DI-96I3000-UNV-DIS+D3-S | 120-277 | 1.1(Max) | 0.90 | 24-32 | 96 | 3000 | 88% | 50000 |
ARC-XX-AAIBBBB-CCC-xYZ-s | CCC | 0.22-1.1 | 0.90 | 24-50 | 60-96 | 1200-3000 | 88% | 50000 |
Technical Parameters
THD | <20%@70-100%load, refer to THD vs. Load curve |
Inrush Current | 50A peak, 1.2ms duration, <0.25A2s@120Vac, Cold Start |
Surge Protection | L-N 2.5KV L/N-PE 2.5KV The RING WAVE is IEC61000-4-12 |
Leakage Current | 0.75mA max @277Vac 60Hz, UL8750 |
Current Accuracy | ±5%Io |
Ripple Current | Ip-p:8%Io max |
Setup Time | 0.75s max |
Short Circuit | Auto recovery. The output recovers when short is removed |
EMC | FCC Part 15 Class A |
Operating Temperature | -20℃~+55℃ ;10%RH~100%RH |
Storage Temperature | -40℃~+85℃; 5%RH~100%RH |
MTBF | ≥320,000 hours, 75℃ case temperature (MIL-HDBK-217F) |
Case Temperature | 90℃ max, marked in the Tc point of label |